NYKM Series

              Molded Case Circuit Breaker

              Compact Safe Wide application Diversity

              PRODUCT OVERVIEW

              NYKM series molded case circuit breaker features small size, high breaking capacity, multiple specifications and full range of accessories, which is widely used in industrial, commercial, residential and infrastructure projects. It can meet customized needs with highly flexible systems to realize intelligent control and management.

              DOUBLE INSULATION DESIGN

              • Adopts dual insulation design to increase the insulation of the product. The insulation voltage level is 1000V, and the molded case is equipped with standard inter-phase spacer, which makes the electricity safer and more adaptable to various operating scenarios.

              FLAME-RETARDANT AND HIGH
              TEMPERATURE RESISTANT CASING

              Adopts flame-retardant and high temperature resistant casing can effectively protect electrical equipment from the threat of fire and high temperature. We pay attention to details and structural stability in design to ensure that the product can operate normally in various harsh environments.

              MULTIPLE TRIPPING MODES

              Thermomagnetic mode

              Overload long delay protection

              Short-circuit instantaneous protection

              Leakage mode

              Overload long delay protection

              Short-circuit instantaneous protection

              Leakage protection

              Electronic display

              Overload long delay protection

              Short-circuit instantaneous protection

              Short-circuit short delay protection

              Grounding fault protection

              485Electrical energy measurement

              Selective coordination

              Technical Parameters

              NYKM2 Series Thermomagnetic Molded Case Circuit Breaker

              Model Rated operating voltage Ue(V) Casing current Inm(A) Rated currentIn(A) Rated insulation voltage Ui(V) Rated impulse withstand voltage Uimp(kV) Number of poles Rated ultimate short -circuit breaking capacity code Short-circuit breaking capacity
              Rated ultimate short-circuit breaking capacity Icu(kA) Rated operating short-circuit breaking capacity Ics(kA)
              400V 690V 400V 690V
              NYKM2-63 AC400 63 10、16、20、25、 32、40、50、63 AC500 AC8 3P L 35 - 18 -
              3P、4P M 50 - 25 -
              NYKM2-100 AC400、AC690 100 16、20、25、32、40、 50、63、80、100 AC800 AC8 3P L 35 20 22 10
              3P、4P M 65 20 35 10
              H 85 20 50 10
              NYKM2-225 AC400、AC690 225 100、125、140、160、 180、200、225 AC800 AC8 3P L 35 20 22 10
              3P、4P M 65 20 35 10
              H 85 20 50 10
              NYKM2-250 AC400、AC690 250 100、125、140、160、 180、200、225、250 AC1000 AC8 3P L 36 20 27 15
              3P、4P M 50 20 40 15
              H 85 20 65 15
              NYKM2-400 AC400、AC690 400 225、250、315、 350、400 AC800 AC8 3P、4P L 50 15 35 10
              M 65 20 42 15
              H 100 20 65 15
              NYKM2-630 AC400、AC690 630 400、500、630 AC800 AC8 3P、4P L 50 15 35 10
              M 65 20 42 15
              H 100 20 65 15
              NYKM2-800 AC400、AC690 800 630、700、800 AC1000 AC8 3P、4P M 75 20 65 15
              H 100 20 75 15
              NYKM2-1250 AC400、AC690 1250 800、1000、1250 AC800 AC8 3P - 65 15 32.5 10

              NYKM2L Series LEAKAGE Molded Case Circuit Breaker

              Model Rated operating voltage Ue(V) Casing current Inm(A) Rated currentIn(A) Rated insulation voltage Ui(V) Rated impulse withstand voltage Uimp(kV) Number of poles Rated ultimate short -circuit breaking capacity code Short-circuit breaking capacity Rated residual short -circuit making (breaking) capacity I△m(kA) Rated residual operating current I△n (mA) Rated residual non -operating current I△no
              Rated ultimate short -circuit breaking capacity Icu(A) Rated operating short -circuit breaking capacity Ics(A)
              NYKM2L-125 AC400 125 16、20、25、32、40、 50、63、80、100、125 AC1000 AC8 3P、4P M 50 35 1/4Icu 100/300/500 1/2I△no
              H 85 50
              NYKM2L-250 AC400 250 100、125、140、 160、180、200、 225、250 AC1000 AC8 3P、4P M 50 35 100/300/500
              H 85 50
              NYKM2L-400 AC400 400 225、250、315、 350、400 AC1000 AC8 3P、4P M 65 42 100/300/500
              H 100 70
              NYKM2L-630 AC400 630 400、500、630 AC1000 AC8 3P、4P M 65 42 300/500/1000
              H 100 70

              NYKM2E Series Electronic Molded Case Circuit Breaker

              Model Rated operating voltage Ue(V) Casing current Inm(A) Rated currentIn(A) Rated insulation voltage Ui(V) Rated impulse withstand voltage Uimp(kV) Number of poles Rated ultimate short -circuit breaking capacity code Short-circuit breaking capacity
              Rated ultimate short-circuit breaking capacity Icu(kA) Rated operating short -circuit breaking capacity Ics(A)
              400V 400V
              NYKM2E-100 AC400 100 16、20、 25、32 32、36、40、45、50、55、 60、63 63、65、70、75、80、85、 90、95、100 AC800 AC8 3P、4P M 50 35
              H 85 50
              NYKM2E-225 AC400 225 100、125、140、160、 180、200、225 AC800 AC8 3P、4P M 65 35
              H 85 50
              NYKM2E-250 AC400 250 100、125、140、160、 180、200、225、250 AC1000 AC8 3P、4P M 50 50
              3P H 85 50
              NYKM2E-400 AC400 400 200、225、250、280、 315、350、400 AC800 AC8 3P、4P M 65 42
              H 100 65
              NYKM2E-800 AC400 800 400、420、440、 460、480、500、 530、560、600、630 630、640、660、 680、700、720、 740、760、780、800 AC800 AC8 3P、4P M 65 42
              H 100 65

              NYKM3 Series Thermomagnetic Molded Case Circuit Breaker r

              Model Rated operating voltage Ue(V) Casing current Inm(A) Rated currentIn(A) Rated insulation voltage Ui(V) Rated impulse withstand voltage Uimp(kV) Number of poles Rated ultimate short -circuit breaking capacity code Rated ultimate short-circuit breaking capacity Icu(kA) Rated operating short -circuit breaking capacity Ics(A)
              415V 690V 415V 690V
              NYKMM3-63 AC415V 63 10、16、20、25、 32、40、50、63 AC1000V AC8 3P、4P L 36 12 36 10
              M 55 12 40 10
              NYKMM3-125 AC415V、AC690V 125 16、20、25、32、40、 50、63、80、100、125 AC1000V AC8 3P、4P L 50 20 40 10
              M 75 20 55 10
              H 100 20 70 10
              NYKMM3-250 AC415V、AC690V 250 100、125、140、160、 180、200、225、250 AC1000V AC12 3P、4P L 50 20 40 10
              M 75 20 55 10
              H 100 20 70 10
              NYKMM3-400 AC415V、AC690V 400 225、250、315、350、 400 AC1000V AC12 3P、4P L 55 20 55 15
              M 75 20 75 15
              H 100 20 85 15
              NYKMM3-630 AC415V、AC690V 630 400、500、630 AC1000V 3P、4P L 55 20 55 15
              M 75 20 75 15
              H 100 20 85 15
              NYKMM3-800 AC415V、AC690V 800 630、700、800 AC1000V 3P、4P M 75 20 75 15
              H 100 20 85 15

              NYKM3L Series LEAKAGE Molded Case Circuit Breaker

              Model Rated operating voltage Ue(V) Casing current Inm(A) Rated currentIn(A) Selective category Rated insulation voltage Ui(V) Rated impulse withstand voltage Uimp(kV) Number of poles Rated ultimate short -circuit breaking capacity code Short-circuit breaking capacity Rated residual short-circuit making (breaking) capacity Rated residual operating current I△n(mA) Rated residual non -operating current I△no
              Rated ultimate short-circuit breaking capacity Icu(kA) Rated operating short -circuit breaking capacity Ics(A) Ⅰ type Ⅱ type
              400V 400V
              NYKM3L-125 400V 125 16A、20A、25A、32A、40A、 50A、63A、80A、100A、125A Category A 1000V 8KV 3 M 50 35 Icu×25% 100、300、500 30、100、300 I△n×50%
              4 M
              3 H 85 50
              4 H
              NYKM3L-250 400V 250 100A、125A、140A、160A、 180A、200A、225A、250A Category A 1000V 8KV 3 M 50 35 Icu×25% 100、300、500 30、100、300 I△n×50%
              4 M
              3 H 85 50
              4 H
              NYKM3L-400 400V 400 225A、250A、315A、 350A、400A Category A 1000V 8KV 3 M 65 42 Icu×25% 100、300、500 300、500、1000 I△n×50%
              4 M
              3 H 100 70
              4 H
              NYKM3L-800 400V 800 630A、700A、800A Category A 1000V 8KV 3 M 65 42 Icu×25% 100、300、500 300、500、1000 I△n×50%
              4 M
              3 H 100 70
              4 H

              NYKM3E Series ELECTRONIC Molded Case Circuit Breaker

              Model Rated operating voltage Ue(V) Casing current Inm(A) Rated currentIn(A) Rated insulation voltage Ui(V) Rated impulse withstand voltage Uimp(kV) Use category Number of poles Rated ultimate short -circuit breaking capacity code Short-circuit breaking capacity
              Rated ultimate short-circuit breaking capacity Icu(kA) Rated operating short -circuit breaking capacity Ics(A)
              400V 690V 400V 690V
              NYKM3E-125 AC415V、 AC690V 32 12、14、16、18、20、22、25、28、30、32 AC1000V AC8 A 3P、4P M 70 20 50 15
              63 25、28、32、36、40、45、50、56、60、63
              125 50、63、70、75、80、85、90、95、100、125 H 85 65
              NYKM3E-250 160 63、70、75、80、90、100、125、140、150、160 A 3P、4P M 70 20 50 10
              250 100、112、125、140、150、160、180、200、225、250 H 85 65
              NYKM3E-400 400 160、180、200、225、250、280、315、350、375、400 B 3P、4P M 70 20 65 15
              H 100 75
              NYKM3E-630 630 250、280、315、350、375、400、450、500、560、630 B 3P M 75 30 65 20
              H 100 75
              NYKM3E-800 630 250、280、315、350、375、400、450、500、560、630 B 3P、4P M 75 30 65 20
              800 315、350、400、450、500、560、630、700、760、800 H 100 75
              Selection table

              NYKM2 250 M P 3 2 00 2 B 250 Installation method
              Product code Housing grade Breaking capacity Operation mode Pole No. Type of tripping device Accessory code Application code N-pole code Rated current Installation method
              NYKM2:
              Thermo -magnetic Molded Case Circuit Breaker
              63A
              100A
              225A
              250A
              400A
              630A
              800A
              1250A
              L:Basic type
              M:Standard type
              H:High breaking type
              Z:Manual operation
              P:Electric operation
              None: Direct operation
              3:3 pole
              4:4 pole
              2:Electro-magnetic type
              3:Thermo-magnetic type
              0:No trip
              Refers to accessory table 2:Motor protection
              None: Power distribution protection
              A:No overcurrent protection, N pole is always switched on
              B:No overcurrent protection, N pole is switched on and off with other three pole
              C:With overcurrent protection, N pole is switched on and off with other three pole
              D:With overcurrent protection, N pole is always switched on
              10A、16A
              20A、25A
              32A、40A
              50A、63A
              80A、100A
              125A、140A
              160A、180A
              200A、225A
              250A、315A
              350A、400A
              630A、700A
              800A、1000A
              1250A
              Fixed wiring at front panel.
              Fixed wiring at rear panel.
              Plug-in wiring at front panel.
              Plug-in wiring at rear panel.
              Withdrawable wiring at front panel.
              Withdrawable wiring at rear panel .

              Note:
              ●   Overload alarm non-tripping device (code 3200I,4200I) is applicable to NYKM2 series molded case circuit breaker 100, 225, 250, 400, 630 housing. However, all specifications of four-pole
              circuit breaker of NYKM2 series with the neutral type C and D type do None overload alarm non-tripping function.
              ●  Standard inter-phase spacer.

              NYKM2L Series Leakage Molded Case Circuit Breaker

              NYKM2L 250 M P 3 2 00 2 B 250 Residual current Relay type Installation method
              Product code Casing grade Breaking capacity Operation mode Pole No. Type of tripping device Accessory code Application code N-pole code Rated current Residual current Relay type Installation method
              NYKM2L:
              Leakage Molded Case Circuit breaker

              125A
              250A
              400A
              630A
              M:Standard type
              H:High breaking type
              Z:Manual operation
              P:Electric operation
              None: Direct operation
              3:3 pole
              4:4 pole
              2:Electro-magnetic type
              3:Thermo-magnetic type
              Refers to accessory table 2:Motor protection
              None: Power distribution protection
              A:No overcurrent protection, N pole is always switched on
              B:No overcurrent protection, N pole is switched on and off with other three pole
              C:With overcurrent protection, N pole is switched on and off with other three pole
              D:With overcurrent protection, N pole is always switched on
              16A
              20A、25A
              32A、40A
              50A、63A
              80A、100A
              125A、140A
              160A、180A
              200A、225A
              250A、315A
              350A、400A
              630A
              100/300/ 500mA
              300/500/1000mA
              Relay type
              Non-relay type
              Fixed wiring at front panel.
              Fixed wiring at rear panel.
              Plug-in wiring at front panel.
              Plug-in wiring at rear panel.
              Withdrawable wiring at front panel.
              Withdrawable wiring at rear panel .

              Note:
              ●  :I: Indicates that the leakage alarm module sends out a signal and the circuit breaker is tripped at the same time.
              ●   II: Indicates that the leakage alarm module sends out a signal and the circuit breaker is not tripped.
              ●   Standard inter-phase spacer

              NYKM2E Series Electronic Molded Case Circuit Breaker

              NYKM2E 250 M P 3 4 00 2 B 250 Installation method
              Product code Casing grade Breaking capacity Operation mode Pole No. Type of tripping device Accessory code Application code N-pole code Rated current Installation method
              NYKM2E:
              Electronic Molded Case Circuit Breaker
              100A
              225A
              250A
              400A
              800A
              L:Basic type
              M:Standard type
              H:High breaking type
              Z:Manual operation
              P:Electric operation
              None: Direct operation
              3:3 pole
              4:4 pole
              4:Electronic display Refers to accessory table 2:Motor protection
              None: Power distribution protection
              A:No overcurrent protection, N pole is always switched on
              B:No overcurrent protection, N pole is switched on and off with other three pole
              C:With overcurrent protection, N pole is switched on and off with other three pole
              D:With overcurrent protection, N pole is always switched on
              32A
              63A
              100A
              225A
              250A
              400A
              630A
              800A
              Fixed wiring at front panel.
              Fixed wiring at rear panel.
              Plug-in wiring at front panel.
              Plug-in wiring at rear panel.
              Withdrawable wiring at front panel.
              Withdrawable wiring at rear panel .

              Note:
              ●   Overload alarm non-tripping module (code 3400I, 4400I) is applicable for NYKM2E series molded case circuit breakers; 100, 225, 250, 400, 800 housing can be equipped with alarm non-tripping module.
              ●  Standard inter-phase spacer

              NYKM3 Series Thermomagnetic Molded Case Circuit Breaker r

              NYKM3 250 M P 3 2 00 2 B 250 Installation method
              Product code Casing grade Breaking capacity Operation mode Pole No. Type of tripping device Accessory code Application code N-pole code Rated current Installation method
              NYKM3:
              Thermo -magnetic Molded Case Circuit Breaker
              63A
              125A
              250A
              400A
              630A
              800A
              L:Basic type
              M:Standard type
              H:High breaking type
              Z:Manual operation
              P:Electric operation
              None: Direct operation
              3:3 pole
              4:4 pole
              2:Electro-magnetic type
              3:Thermo-magnetic type
              0:No trip
              Refers to accessory table 2:Motor protection
              None: Power distribution protection
              A:No overcurrent protection, N pole is always switched on
              B:No overcurrent protection, N pole is switched on and off with other three pole
              C:With overcurrent protection, N pole is switched on and off with other three pole
              D:With overcurrent protection, N pole is always switched on
              10A、16A
              20A、25A
              32A、40A
              50A、63A
              80A、100A
              125A、140A
              160A、180A
              200A、225A
              250A、315A
              350A、400A
              630A、700A
              800A
              Fixed wiring at front panel.
              Fixed wiring at rear panel.
              Plug-in wiring at front panel.
              Plug-in wiring at rear panel.
              Withdrawable wiring at front panel.
              Withdrawable wiring at rear panel .

              Note:
              ●   Overload alarm non-tripping device (code 3200I,4200I) is applicable to NYKM3 series molded case circuit breaker 100, 225, 250, 400, 630 housing. However, all specifications of four-pole circuit breaker of NYKM3 series with the neutral type C and D type do None overload alarm non-tripping function.
              ●  Standard inter-phase spacer.

              NYKM3L Series LEAKAGE Molded Case Circuit Breaker

              NYKM3L 250 M P 3 2 00 2 B 250 Residual current Non-relay type Installation method
              Product code Casing grade Breaking capacity Operation mode Pole No. Type of tripping device Accessory code Application code N-pole code Rated current Residual current Relay type Installation method
              NYKM3L:
              Leakage Molded Case Circuit Breaker
              125A
              250A
              400A
              800A
              M:Standard type
              H:High breaking type
              Z:Manual operation
              P:Electric operation
              None: Direct operation
              3:3 pole
              4:4 pole
              2:Electro-magnetic type
              3:Thermo-magnetic type
              Refers to accessory table 2:Motor protection
              None: Power distribution protection
              A:No overcurrent protection, N pole is always switched on
              B:No overcurrent protection, N pole is switched on and off with other three pole
              C:With overcurrent protection, N pole is switched on and off with other three pole
              D:With overcurrent protection, N pole is always switched on
              16A
              20A、25A
              32A、40A
              50A、63A
              80A、100A
              125A、140A
              160A、180A
              200A、225A
              250A、315A
              350A、400A
              630A、700A
              800A
              100/300/500mA
              300/500/1000mA
              Relay type
              Non-relay type
              Fixed wiring at front panel.
              Fixed wiring at rear panel.
              Plug-in wiring at front panel.
              Plug-in wiring at rear panel.
              Withdrawable wiring at front panel.
              Withdrawable wiring at rear panel .

              Note: ●   I: Indicates that the leakage alarm module sends out a signal and the circuit breaker is tripped at the same time.
              ●  II: Indicates that the leakage alarm module sends out a signal and the circuit breaker is not tripped.
              ●  Standard inter-phase spacer

              NYKM3E Series ELECTRONIC Molded Case Circuit Breaker

              NYKM3E 250 M P 3 4 00 2 B 250 Installation method
              Product code Casing grade Breaking capacity Operation mode Pole No. Type of tripping device Accessory code Application code N-pole code Rated current Installation method
              NYKM3L:
              Electronic Molded Case Circuit Breaker
              125A
              250A
              400A
              630A
              800A
              L:Basic type
              M:Standard type
              H:High breaking type
              Z:Manual operation
              P:Electric operation
              None: Direct operation
              3:3 pole
              4:4 pole
              4:Electronic display Refers to accessory table 2:Motor protection
              None: Power distribution protection
              A:No overcurrent protection, N pole is always switched on
              B:No overcurrent protection, N pole is switched on and off with other three pole
              C:With overcurrent protection, N pole is switched on and off with other three pole
              D:With overcurrent protection, N pole is always switched on
              125A
              250A
              400A
              630A
              800A
              Fixed wiring at front panel.
              Fixed wiring at rear panel.
              Plug-in wiring at front panel.
              Plug-in wiring at rear panel.
              Withdrawable wiring at front panel.
              Withdrawable wiring at rear panel .

              Note:
              ●   Overload alarm non-tripping module (code 3400I, 4400I) is applicable for NYKM3E series molded case circuit breakers; 100, 225, 250, 400, 800 housing can be equipped with alarm non-tripping module.
              ●  Standard inter-phase spacer

              Technical Parameters

              NYKM2 Series Thermomagnetic Molded Case Circuit Breaker

              • Rated operating voltage Ue(V) :AC400

                Casing current Inm(A) :63

                Rated currentIn(A):10、16、20、25、 32、40、50、63

                Rated insulation voltage Ui(V):AC500

                Rated impulse withstand voltage Uimp(kV):AC8

                Number of poles :3P/3P、4P

                Rated ultimate short -circuit breaking capacity code:L/M

                Rated ultimate short-circuit breaking capacity Icu(kA) ):
                35/50(400V);-(690V)

                Rated operating short-circuit breaking capacity Ics(kA) :
                18/25(400V);-(690V)

              • Rated operating voltage Ue(V) :AC400、AC690

                Casing current Inm(A) :100

                Rated currentIn(A):16、20、25、32、40、 50、63、80、100

                Rated insulation voltage Ui(V):AC800

                Rated impulse withstand voltage Uimp(kV):AC8

                Number of poles :3P/3P、4P/3P、4P

                Rated ultimate short -circuit breaking capacity code:L/M/H

                Rated ultimate short-circuit breaking capacity Icu(kA) ):
                35/65/85(400V);20(690V)

                Rated operating short-circuit breaking capacity Ics(kA) :
                22/35/50(400V);10(690V)

              • Rated operating voltage Ue(V) :AC400、AC690

                Casing current Inm(A) :225

                Rated currentIn(A):100、125、140、160、 180、200、225

                Rated insulation voltage Ui(V):AC800

                Rated impulse withstand voltage Uimp(kV):AC8

                Number of poles :3P/3P、4P/3P、4P

                Rated ultimate short -circuit breaking capacity code:L/M/H

                Rated ultimate short-circuit breaking capacity Icu(kA) ):
                35/65/85(400V);20(690V)

                Rated operating short-circuit breaking capacity Ics(kA) :
                22/35/50(400V);10(690V)

              • Rated operating voltage Ue(V) :AC400、AC690

                Casing current Inm(A) :250

                Rated currentIn(A):100、125、140、160、 180、200、225、250

                Rated insulation voltage Ui(V):AC1000

                Rated impulse withstand voltage Uimp(kV):AC8

                Number of poles :3P/3P、4P/3P、4P

                Rated ultimate short -circuit breaking capacity code:L/M/H

                Rated ultimate short-circuit breaking capacity Icu(kA) ):
                36/50/85(400V);20(690V)

                Rated operating short-circuit breaking capacity Ics(kA) :
                27/40/65 (400V);15(690V)

              • Rated operating voltage Ue(V) :AC400、AC690

                Casing current Inm(A) :400

                Rated currentIn(A):225、250、315、 350、400

                Rated insulation voltage Ui(V):AC800

                Rated impulse withstand voltage Uimp(kV):AC8

                Number of poles :3P、4P

                Rated ultimate short -circuit breaking capacity code:L/M/H

                Rated ultimate short-circuit breaking capacity Icu(kA) ):
                50/65/100(400V); 15/20/20(690V)

                Rated operating short-circuit breaking capacity Ics(kA) :
                35/42/65(400V); 10/15/15(690V)

              • Rated operating voltage Ue(V) :AC400、AC690

                Casing current Inm(A) :630

                Rated currentIn(A):400、500、630

                Rated insulation voltage Ui(V):AC800

                Rated impulse withstand voltage Uimp(kV):AC8

                Number of poles :3P、4P

                Rated ultimate short -circuit breaking capacity code:L/M/H

                Rated ultimate short-circuit breaking capacity Icu(kA) ):
                50/65/100(400V); 15/20/20 (690V)

                Rated operating short-circuit breaking capacity Ics(kA) :
                35/42/65 (400V);10/15/15(690V)

              • Rated operating voltage Ue(V) :AC400、AC690

                Casing current Inm(A) :800

                Rated currentIn(A):630、700、800

                Rated insulation voltage Ui(V):AC1000

                Rated impulse withstand voltage Uimp(kV):AC8

                Number of poles :3P、4P

                Rated ultimate short -circuit breaking capacity code:M/H

                Rated ultimate short-circuit breaking capacity Icu(kA) ):
                75/100 (400V);20(690V)

                Rated operating short-circuit breaking capacity Ics(kA) :
                65/75 (400V);15(690V)

              • Rated operating voltage Ue(V) :AC400、AC690

                Casing current Inm(A) :1250

                Rated currentIn(A):800、1000、1250

                Rated insulation voltage Ui(V):AC800

                Rated impulse withstand voltage Uimp(kV):AC8

                Number of poles :3P

                Rated ultimate short -circuit breaking capacity code:-

                Rated ultimate short-circuit breaking capacity Icu(kA) ):65(400V);15(690V)

                Rated operating short-circuit breaking capacity Ics(kA) :32.5(400V);10(690V)

              NYKM2L Series Leakage Molded Case Circuit Breaker

              • Rated operating voltage Ue(V) :AC400

                Casing current Inm(A) :125

                Rated currentIn(A):16、20、25、32、40、 50、63、80、100、125

                Rated insulation voltage Ui(V):AC1000

                Rated impulse withstand voltage Uimp(kV):AC8

                Number of poles :3P、4P

                Rated ultimate short -circuit breaking capacity code:M/H

                Rated ultimate short-circuit breaking capacity Icu(kA) ):50/85

                Rated operating short-circuit breaking capacity Ics(kA) :35/50

                Rated residual short -circuit making (breaking) capacity I△m(kA) :1/4Icu

                Rated residual operating current I△n (mA) :100/300/500

                Rated residual non -operating current I△no:1/2I △no

              • Rated operating voltage Ue(V) :AC400

                Casing current Inm(A) :250

                Rated currentIn(A):100、125、140、160、180、200、225、250

                Rated insulation voltage Ui(V):AC1000

                Rated impulse withstand voltage Uimp(kV):AC8

                Number of poles :3P、4P

                Rated ultimate short -circuit breaking capacity code:M/H

                Rated ultimate short-circuit breaking capacity Icu(kA) ):50/85

                Rated operating short-circuit breaking capacity Ics(kA) :35/50

                Rated residual short -circuit making (breaking) capacity I△m(kA) :1/4Icu

                Rated residual operating current I△n (mA) :100/300/500

                Rated residual non -operating current I△no:1/2I △no

              • Rated operating voltage Ue(V) :AC400

                Casing current Inm(A) :400

                Rated currentIn(A):225、250、315、350、400

                Rated insulation voltage Ui(V):AC1000

                Rated impulse withstand voltage Uimp(kV):AC8

                Number of poles :3P、4P

                Rated ultimate short -circuit breaking capacity code:M/H

                Rated ultimate short-circuit breaking capacity Icu(kA) ):65/100

                Rated operating short-circuit breaking capacity Ics(kA) :42/70

                Rated residual short -circuit making (breaking) capacity I△m(kA) :1/4Icu

                Rated residual operating current I△n (mA) :100/300/500

                Rated residual non -operating current I△no:1/2I △no

              • Rated operating voltage Ue(V) :AC400

                Casing current Inm(A) :630

                Rated currentIn(A):400、500、630

                Rated insulation voltage Ui(V):AC1000

                Rated impulse withstand voltage Uimp(kV):AC8

                Number of poles :3P、4P

                Rated ultimate short -circuit breaking capacity code:M/H

                Rated ultimate short-circuit breaking capacity Icu(kA) ):65/100

                Rated operating short-circuit breaking capacity Ics(kA) :42/70

                Rated residual short -circuit making (breaking) capacity I△m(kA) :1/4Icu

                Rated residual operating current I△n (mA) :300/500/100

                Rated residual non -operating current I△no:1/2I △no

              NYKM2E Series Electronic Molded Case Circuit Breaker

              • Rated operating voltage Ue(V) :AC400

                Casing current Inm(A) :100

                Rated currentIn(A):16、20、25、32/ 32、36、40、45、50、55、60、63/63、65、70、75、80、85、90、95、100

                Rated insulation voltage Ui(V):AC800

                Rated impulse withstand voltage Uimp(kV):AC8

                Number of poles :3P、4P

                Rated ultimate short -circuit breaking capacity code:M/H

                Rated ultimate short-circuit breaking capacity Icu(kA) : 50 / 85 (400V)

                Rated operating short-circuit breaking capacity Ics(kA) : 35 / 50 (400V)

              • Rated operating voltage Ue(V) :AC400

                Casing current Inm(A) :225

                Rated currentIn(A):100、125、140、160、180、200、225

                Rated insulation voltage Ui(V):AC800

                Rated impulse withstand voltage Uimp(kV):AC8

                Number of poles :3P、4P

                Rated ultimate short -circuit breaking capacity code:M/H

                Rated ultimate short-circuit breaking capacity Icu(kA) : 65 / 85 (400V)

                Rated operating short-circuit breaking capacity Ics(kA) : 35 / 50 (400V)

              • Rated operating voltage Ue(V) :AC400

                Casing current Inm(A) :250

                Rated currentIn(A):100、125、140、160、180、200、225、250

                Rated insulation voltage Ui(V):AC1000

                Rated impulse withstand voltage Uimp(kV):AC8

                Number of poles :3P、4P/3P

                Rated ultimate short -circuit breaking capacity code:M/H

                Rated ultimate short-circuit breaking capacity Icu(kA) :50 / 85 (400V)

                Rated operating short-circuit breaking capacity Ics(kA) :50 / 50 (400V)

              • Rated operating voltage Ue(V) :AC400

                Casing current Inm(A) :400

                Rated currentIn(A):200、225、250、280、 315、350、400

                Rated insulation voltage Ui(V):AC800

                Rated impulse withstand voltage Uimp(kV):AC8

                Number of poles :3P、4P

                Rated ultimate short -circuit breaking capacity code:M/H

                Rated ultimate short-circuit breaking capacity Icu(kA) :65 / 100 (400V)

                Rated operating short-circuit breaking capacity Ics(kA) :42 / 65 (400V)

              • Rated operating voltage Ue(V) :AC400

                Casing current Inm(A) :800

                Rated currentIn(A):400、420、440、460、480、500、530、560、600、630 / 630、640、660、680、700、720、740、760、780、800

                Rated insulation voltage Ui(V):AC800

                Rated impulse withstand voltage Uimp(kV):AC8

                Number of poles :3P、4P

                Rated ultimate short -circuit breaking capacity code:M/H

                Rated ultimate short-circuit breaking capacity Icu(kA) : 65 / 100(400V)

                Rated operating short-circuit breaking capacity Ics(kA) : 42 / 65(400V)

              NYKM3 Series Thermomagnetic Molded Case Circuit Breaker r

              • Rated operating voltage Ue(V) :AC415

                Casing current Inm(A) :63

                Rated currentIn(A):10、16、20、25、 32、40、50、63

                Rated insulation voltage Ui(V):AC1000

                Rated impulse withstand voltage Uimp(kV):AC8

                Number of poles :3P、4P

                Rated ultimate short -circuit breaking capacity code:L/M

                Rated ultimate short-circuit breaking capacity Icu(kA) :36 / 55 (415V);12(690V)

                Rated operating short-circuit breaking capacity Ics(kA) :36 / 40 (415V);10(690V)

              • Rated operating voltage Ue(V) :AC415、AC690V

                Casing current Inm(A) :125

                Rated currentIn(A):16、20、25、32、40、 50、63、80、100、125

                Rated insulation voltage Ui(V):AC1000

                Rated impulse withstand voltage Uimp(kV):AC8

                Number of poles :3P、4P

                Rated ultimate short -circuit breaking capacity code:L/M/H

                Rated ultimate short-circuit breaking capacity Icu(kA) :50 / 75 / 100 (415V);20(690V)

                Rated operating short-circuit breaking capacity Ics(kA) :40 / 55 / 70 (415V);10(690V)

              • Rated operating voltage Ue(V) :AC415、AC690V

                Casing current Inm(A) :250

                Rated currentIn(A):100、125、140、160、 180、200、225、250

                Rated insulation voltage Ui(V):AC1000

                Rated impulse withstand voltage Uimp(kV):AC12

                Number of poles :3P、4P

                Rated ultimate short -circuit breaking capacity code:L/M/H

                Rated ultimate short-circuit breaking capacity Icu(kA) :50 / 75 / 100 (415V);20(690V)

                Rated operating short-circuit breaking capacity Ics(kA) :40 / 55 / 70 (415V);10(690V)

              • Rated operating voltage Ue(V) :AC415、AC690V

                Casing current Inm(A) :400

                Rated currentIn(A):225、250、315、350、 400

                Rated insulation voltage Ui(V):AC1000

                Rated impulse withstand voltage Uimp(kV):AC12

                Number of poles :3P、4P

                Rated ultimate short -circuit breaking capacity code:L/M/H

                Rated ultimate short-circuit breaking capacity Icu(kA) :55 / 75 / 100 (415V);20(690V)

                Rated operating short-circuit breaking capacity Ics(kA) :55 / 75 / 85 (415V);15(690V)

              • Rated operating voltage Ue(V) :AC415、AC690V

                Casing current Inm(A) :630

                Rated currentIn(A):400、500、630

                Rated insulation voltage Ui(V):AC1000

                Rated impulse withstand voltage Uimp(kV):AC12

                Number of poles :3P、4P

                Rated ultimate short -circuit breaking capacity code:L/M/H

                Rated ultimate short-circuit breaking capacity Icu(kA) :55 / 75 / 100 (415V);20(690V)

                Rated operating short-circuit breaking capacity Ics(kA) :55 / 75 / 85 (415V);15(690V)

              • Rated operating voltage Ue(V) :AC415、AC690V

                Casing current Inm(A) :800

                Rated currentIn(A):630、700、800

                Rated insulation voltage Ui(V):AC1000

                Rated impulse withstand voltage Uimp(kV):AC12

                Number of poles :3P、4P

                Rated ultimate short -circuit breaking capacity code:M/H

                Rated ultimate short-circuit breaking capacity Icu(kA) : 75 / 100 (415V);20(690V)

                Rated operating short-circuit breaking capacity Ics(kA) :75 / 85 (415V);15(690V)

              NYKM3L Series LEAKAGE Molded Case Circuit Breaker

              • Rated operating voltage Ue (V):400V

                Casing current Inm(A) :126

                Rated currentIn(A):16A、20A、25A、32A、40A、 50A、63A、80A、100A、125A

                Selective category :Category A

                Rated insulation voltage Ui(V):1000V

                Rated impulse withstand voltage Uimp(kV):8KV

                Number of poles :3 / 4 / 3 / 4

                Rated ultimate short -circuit breaking capacity code:M / M / H / H

                Rated ultimate short-circuit breaking capacity Icu(kA) :50 / 50 / 85 / 85 (400V)

                Rated operating short-circuit breaking capacity Ics(kA) :35 / 35 / 50 / 50 (400V)

                Rated residual short-circuit making (breaking) capacity:Icu×25%

                Rated residual operating current I△n (mA) :100、300、500 (Ⅰ type);30、100、300 (Ⅱ type)

                Rated residual non -operating current I△no :I△n×50%

              • Rated operating voltage Ue (V):400V

                Casing current Inm(A) :250

                Rated currentIn(A):100A、125A、140A、160A、 180A、200A、225A、250A

                Selective category :Category A

                Rated insulation voltage Ui(V):1000V

                Rated impulse withstand voltage Uimp(kV):8KV

                Number of poles :3 / 4 / 3 / 4

                Rated ultimate short -circuit breaking capacity code:M / M / H / H

                Rated ultimate short-circuit breaking capacity Icu(kA) :50 / 50 / 85 / 85 (400V)

                Rated operating short-circuit breaking capacity Ics(kA) :35 / 35 / 50 / 50 (400V)

                Rated residual short-circuit making (breaking) capacity:Icu×25%

                Rated residual operating current I△n (mA) :100、300、500 (Ⅰ type);30、100、300 (Ⅱ type)

                Rated residual non -operating current I△no :I△n×50%

              • Rated operating voltage Ue (V):400V

                Casing current Inm(A) :400

                Rated currentIn(A):225A、250A、315A、 350A、400A

                Selective category :Category A

                Rated insulation voltage Ui(V):AC1000V

                Rated impulse withstand voltage Uimp(kV):8KV

                Number of poles :3 / 4 / 3 / 4

                Rated ultimate short -circuit breaking capacity code:M / M / H / H

                Rated ultimate short-circuit breaking capacity Icu(kA) :65 / 65 / 100 / 100 (400V)

                Rated operating short-circuit breaking capacity Ics(kA) :42 / 42 / 70 / 70 (400V)

                Rated residual short-circuit making (breaking) capacity:Icu×25%

                Rated residual operating current I△n (mA) :100、300、500 (Ⅰ type);300、500、1000 (Ⅱ type)

                Rated residual non -operating current I△no :I△n×50%

              • Rated operating voltage Ue (V):400V

                Casing current Inm(A) :800

                Rated currentIn(A):630A、700A、800A

                Selective category :Category A

                Rated insulation voltage Ui(V):AC1000V

                Rated impulse withstand voltage Uimp(kV):8KV

                Number of poles :3 / 4 / 3 / 4

                Rated ultimate short -circuit breaking capacity code:M / M / H / H

                Rated ultimate short-circuit breaking capacity Icu(kA) :65 / 65 / 100 / 100 (400V)

                Rated operating short-circuit breaking capacity Ics(kA) :42 / 42 / 70 / 70 (400V)

                Rated residual short-circuit making (breaking) capacity:Icu×25%

                Rated residual operating current I△n (mA) :100、300、500 (Ⅰ type);300、500、1000 (Ⅱ type)

                Rated residual non -operating current I△no :I△n×50%

              NYKM3E Series ELECTRONIC Molded Case Circuit Breaker

              • Rated operating voltage Ue (V):AC415V、 AC690V

                Casing current Inm(A) :32/63/125

                Rated currentIn(A):12、14、16、18、20、22、25、28、30、32 / 25、28、32、36、40、45、50、56、60、63 / 50、63、70、75、80、85、90、95、100、125

                Rated insulation voltage Ui(V):AC1000V

                Rated impulse withstand voltage Uimp(kV):AC8

                Use category :A

                Number of poles :3P、4P

                Rated ultimate short -circuit breaking capacity code: M / H

                Rated ultimate short-circuit breaking capacity Icu(kA) :70 / 85 (400V);20(690V)

                Rated operating short-circuit breaking capacity Ics(kA) :50 / 65 (400V);15(690V)

              • Rated operating voltage Ue (V):AC415V、 AC690V

                Casing current Inm(A) :160/250

                Rated currentIn(A):63、70、75、80、90、100、125、140、150、160 / 100、112、125、140、150、160、180、200、225、250

                Rated insulation voltage Ui(V):AC1000V

                Rated impulse withstand voltage Uimp(kV):AC8

                Use category :A

                Number of poles :3P、4P

                Rated ultimate short -circuit breaking capacity code: M / H

                Rated ultimate short-circuit breaking capacity Icu(kA) :70 / 85 (400V);20(690V)

                Rated operating short-circuit breaking capacity Ics(kA) :50 / 65 (400V);10(690V)

              • Rated operating voltage Ue (V):AC415V、 AC690V

                Casing current Inm(A) :400

                Rated currentIn(A):160、180、200、225、250、280、315、350、375、400

                Rated insulation voltage Ui(V):AC1000V

                Rated impulse withstand voltage Uimp(kV):AC8

                Use category :B

                Number of poles :3P、4P

                Rated ultimate short -circuit breaking capacity code: M / H

                Rated ultimate short-circuit breaking capacity Icu(kA) :70 / 100 (400V);20(690V)

                Rated operating short-circuit breaking capacity Ics(kA) :65 / 75 (400V);15(690V)

              • Rated operating voltage Ue (V):AC415V、 AC690V

                Casing current Inm(A) :630

                Rated currentIn(A):250、280、315、350、375、400、450、500、560、630

                Rated insulation voltage Ui(V):AC1000V

                Rated impulse withstand voltage Uimp(kV):AC8

                Use category :B

                Number of poles :3P

                Rated ultimate short -circuit breaking capacity code: M / H

                Rated ultimate short-circuit breaking capacity Icu(kA) :75 / 100 (400V);30(690V)

                Rated operating short-circuit breaking capacity Ics(kA) :65 / 75 (400V);20(690V)

              • Rated operating voltage Ue (V):AC415V、 AC690V

                Casing current Inm(A) :630/800

                Rated currentIn(A):250、280、315、350、375、400、450、500、560、630 / 315、350、400、450、500、560、630、700、760、800

                Rated insulation voltage Ui(V):AC1000V

                Rated impulse withstand voltage Uimp(kV):AC8

                Use category :B

                Number of poles :3P、4P

                Rated ultimate short -circuit breaking capacity code: M / H

                Rated ultimate short-circuit breaking capacity Icu(kA) :75 / 100 (400V);30(690V)

                Rated operating short-circuit breaking capacity Ics(kA) :65 / 75 (400V);20(690V)

              Selection table


              • Product code :NYKM2:Thermo -magnetic Molded Case Circuit Breaker

                Casing grade:63A、100A、225A、 250A、400A、630A、800A、1250A

                Breaking capacity :L:Basic type、M:Standard type、 H:High breaking type

                Operation mode:Z:Manual operation、P:Electric operation、None: Direct operation

                Pole No.:3:3 pole、4:4 pole

                Type of tripping device:2:Electro-magnetic type 、3:Thermo-magnetic type 、0:No trip

                Accessory code:Refers to accessory table

                Application code:2:Motor protection 、None: Power distribution protection

                N-pole code:A:No overcurrent protection, N pole is always switched on、B:No overcurrent protection, N pole is switched on and off with other three pole、C:With overcurrent protection, N pole is switched on and off with other three pole、D:With overcurrent protection, N pole is always switched on

                Rated current:10A、16A、20A、25A 、32A、40A 、50A、63A、0A、100A、125A、140A 、160A、180A、200A、225A、250A、315A、350A、400A 、630A、700A、800A、1000A、1250A

                Installation method:Fixed wiring at front panel.、Fixed wiring at rear panel.、Plug-in wiring at front panel.、Plug-in wiring at rear panel.、Withdrawable wiring at front panel.、Withdrawable wiring at rear panel .

              Note: ?   Overload alarm non-tripping device (code 3200I,4200I) is applicable to NYKM2 series molded case circuit breaker 100, 225, 250, 400, 630 housing. However, all specifications of four-pole circuit breaker of NYKM2 series with the neutral type C and D type do None overload alarm non-tripping function.Standard inter-phase spacer.
              ?  Standard inter-phase spacer.

              • Product code :NYKM2L Series Leakage Molded Case Circuit Breaker

                Casing grade:125A、250A、400A、630A

                Breaking capacity :M:Standard type、 H:High breaking type

                Operation mode:Z:Manual operation、P:Electric operation、None: Direct operation

                Pole No.:3:3 pole、4:4 pole

                Type of tripping device:2:Electro-magnetic type 、3:Thermo-magnetic type

                Accessory code:Refers to accessory table

                Application code:2:Motor protection 、None: Power distribution protection

                N-pole code:A:No overcurrent protection, N pole is always switched on、B:No overcurrent protection, N pole is switched on and off with other three pole、C:With overcurrent protection, N pole is switched on and off with other three pole、D:With overcurrent protection, N pole is always switched on

                Rated current:16A、20A、25A 、32A、40A 、50A、63A、0A、100A、125A、140A 、160A、180A、200A、225A、250A、315A、350A、400A 、630A

                Residual current :100/300/500mA/ 300/500/1000mA

                Relay type:Relay type 、Non-relay type

                Installation method:Fixed wiring at front panel.、Fixed wiring at rear panel.、Plug-in wiring at front panel.、Plug-in wiring at rear panel.、Withdrawable wiring at front panel.、Withdrawable wiring at rear panel .

              注:?   I: Indicates that the leakage alarm module sends out a signal and the circuit breaker is tripped at the same time.
              II: Indicates that the leakage alarm module sends out a signal and the circuit breaker is not tripped.
              ?  Standard inter-phase spacer

              • Product code:NYKM2E: Electronic Molded Case Circuit Breaker

                Casing grade:100A、225A、250A、400A、800A

                Breaking capacity:M:Standard type、 H:High breaking type

                Operation mode:Z:Manual operation、P:Electric operation、None: Direct operation

                Pole No.:3:3 pole、4:4 pole

                Type of tripping device:4:Electronic display

                Accessory code:Refers to accessory table

                Application code:2:Motor protection 、None: Power distribution protection

                N-pole code:A:No overcurrent protection, N pole is always switched on、B:No overcurrent protection, N pole is switched on and off with other three pole、C:With overcurrent protection, N pole is switched on and off with other three pole、D:With overcurrent protection, N pole is always switched on

                Rated current:32A、63A、100A、225A、250A、400A 、630A、800A

                Installation method:Fixed wiring at front panel.、Fixed wiring at rear panel.、Plug-in wiring at front panel.、Plug-in wiring at rear panel.、Withdrawable wiring at front panel.、Withdrawable wiring at rear panel .

              注:?  :Note: Overload alarm non-tripping module (code 3400I, 4400I) is applicable for NYKM2E series molded case circuit breakers; 100, 225, 250, 400, 800 housing can be equipped with alarm non-tripping module.

              ?   Standard inter-phase spacer

              • Product code :NYKM3:Thermo -magnetic Molded Case Circuit Breaker

                Casing grade:63A、125A、250A、400A 630A、800A

                Breaking capacity :M:Standard type、 H:High breaking type、H:High breaking type

                Operation mode:Z:Manual operation、P:Electric operation、None: Direct operation

                Pole No.:3:3 pole、4:4 pole

                Type of tripping device:2:Electro-magnetic type 、3:Thermo-magnetic type 、0:No trip

                Accessory code:Refers to accessory table

                Application code:2:Motor protection 、None: Power distribution protection

                N-pole code:A:No overcurrent protection, N pole is always switched on、B:No overcurrent protection, N pole is switched on and off with other three pole、C:With overcurrent protection, N pole is switched on and off with other three pole、D:With overcurrent protection, N pole is always switched on

                Rated current:16A、20A、25A 、32A、40A 、50A、63A、0A、100A、125A、140A 、160A、180A、200A、225A、250A、315A、350A、400A 、630A、700A、800A

                Installation method:Fixed wiring at front panel.、Fixed wiring at rear panel.、Plug-in wiring at front panel.、Plug-in wiring at rear panel.、Withdrawable wiring at front panel.、Withdrawable wiring at rear panel .

              注:?  Note: Overload alarm non-tripping device (code 3200I,4200I) is applicable to NYKM3 series molded case circuit breaker 100, 225, 250, 400, 630 housing. However, all specifications of four-pole circuit breaker of NYKM3 series with the neutral type C and D type do None overload alarm non-tripping function.
              ?  Standard inter-phase spacer.

              • Product code :NYKM3L :Series Leakage Molded Case Circuit Breaker

                Casing grade:125A、250A、400A、800A

                Breaking capacity :M:Standard type、 H:High breaking type

                Operation mode:Z:Manual operation、P:Electric operation、None: Direct operation

                Pole No.:3:3 pole、4:4 pole

                Type of tripping device:2:Electro-magnetic type 、3:Thermo-magnetic type

                Accessory code:Refers to accessory table

                Application code:2:Motor protection 、None: Power distribution protection

                N-pole code:A:No overcurrent protection, N pole is always switched on、B:No overcurrent protection, N pole is switched on and off with other three pole、C:With overcurrent protection, N pole is switched on and off with other three pole、D:With overcurrent protection, N pole is always switched on

                Rated current:16A、20A、25A 、32A、40A 、50A、63A、0A、100A、125A、140A 、160A、180A、200A、225A、250A、315A、350A、400A 、630A、700A、800A

                Residual current :100/300/ 500mA、 300/500/1000mA

                Relay type:Relay type 、Non-relay type

                Installation method:Fixed wiring at front panel.、Fixed wiring at rear panel.、Plug-in wiring at front panel.、Plug-in wiring at rear panel.、Withdrawable wiring at front panel.、Withdrawable wiring at rear panel .

              Note: ?   I: Indicates that the leakage alarm module sends out a signal and the circuit breaker is tripped at the same time.
              ?   II: Indicates that the leakage alarm module sends out a signal and the circuit breaker is not tripped.
              ?   Standard inter-phase spacer

              • Product code :NYKM3E: Electronic Molded Case Circuit Breaker

                Casing grade:125A、250A、400A、630A、800A

                Breaking capacity :L:Basic type、M:Standard type、 H:High breaking type

                Operation mode:Z:Manual operation、P:Electric operation、None: Direct operation

                Pole No.:3:3 pole、4:4 pole

                Type of tripping device:4:Electronic display

                Accessory code:Refers to accessory table

                Application code:2:Motor protection 、None: Power distribution protection

                N-pole code:A:No overcurrent protection, N pole is always switched on、B:No overcurrent protection, N pole is switched on and off with other three pole、C:With overcurrent protection, N pole is switched on and off with other three pole、D:With overcurrent protection, N pole is always switched on

                Rated current:125A、250A、400A、630A、800A

                Installation method:Fixed wiring at front panel.、Fixed wiring at rear panel.、Plug-in wiring at front panel.、Plug-in wiring at rear panel.、Withdrawable wiring at front panel.、Withdrawable wiring at rear panel .

              Note:?   Overload alarm non-tripping module (code 3400I, 4400I) is applicable for NYKM3E series molded case circuit breakers; 100, 225, 250, 400, 800 housing can be equipped with alarm non-tripping module.
              ?   Standard inter-phase spacer

              page top