KLD-UPQC Series

              Comprehensive Power Quality Control Equipment

              As a kind of power quality control equipment with comprehensive compensation capability, it directly controls the power quality of the whole low-voltage electrical system, and can simultaneously meet the requirements of voltage and current quality problems for users.

              PRODUCT OVERVIEW

              Electricity is one of the prerequisites for social development. With the development of social economy, the increasing amount of electric load, the continuous advancement of electric power industry and the growing installed capacity of power grid, the contradiction between the supply and demand of power is gradually no longer the main contradiction of the power system. Power quality problems include many aspects, such as voltage quality, current quality, power supply quality and power consumption quality. Due to the nonlinear characteristics of the power system, system faults and nonlinear loads and other issues, power distribution network has various power quality issues; at the same time, the automation and intelligence of the production process and life as well as a variety of complex precise equipment raise higher demands for the power quality, thus the unified power quality control has become the pressing issue that needs to be addressed.

              As an power technology equipment, KLD-UPQC series comprehensive power quality control equipment is characterized by superior performance and comprehensive function, which can be used to solve a variety of power quality problems of the distribution network. As a power quality control equipment with comprehensive compensation capability, it directly controls the power quality of the whole low-voltage electrical system, and can simultaneously meet the requirements of voltage and current quality problems for users.

              CONNECTION MODE

              KLD-UPQC is connected between the grid and the load, and the maintenance bypass switch is optional. The maintenance bypass switch turns off when a system fault occurs so that the system can be serviced.

              POWER QUALITY

              Power quality refers to the physical characteristics of a power supply equipment that does not interrupts and interferes with the electricity consumption by users under normal operating conditions.

              PRODUCT CHARACTERITICS

              Redundant design does not affect the reliability and continuity of the power supply, ensuring the load can be operated normally and continuously

              Adopts three-level inverter to improve the efficiency of the whole equipment, reduce losses and save power

              Control voltage dips and rises

              Control voltage harmonic distortion and current harmonic distortion of power supply system

              Reduce line loss, increase output power of the transformer, improve power factor of the system, and stabilize the voltage of power supply

              Improve grid efficiency and power quality of the power supply system

              Grid power factor is close to 1 after controlling within the range of equipment capacity, and the total harmonic filtering rate is more than 97%

              DSP intelligent monitoring, high-speed detection and operation ensure accurate and effective detection and compensation control

              Standard modular design, module or component (plug-in unit) structure for power circuit and control circuit. The same module can be interchanged to enhance the reliability and repairability in use

              Small and lightweight design has low requirements for space

              Daily maintenance-free

              Technical Parameters

              Input
              Rated AC input voltage 208V-480V(other voltage levels can be customized)
              Input Voltage range -15%~+15%
              Grid frequency range 50Hz/60Hz±5Hz
              Wiring mode Three-phase three-wire/three-phase four-wire
              Multiple pcs in parallel Support multi-module parallel connection
              Output
              OutputFrequency 50±0.01Hz or 60±0.01Hz
              Power factor 0.99
              Voltage harmonic ≤3%
              Overload capacity 200%
              Performance indicators
              Fast response time <100us
              Full response time <2.5ms
              Noise ≤60db(100% load)
              Heat dissipation mode Intelligent air cooling
              Protection functions Short-circuit protection, DC busbar undervoltage/overvoltage protection, power semiconductor fault protection, overload protection, etc.
              Application environment
              Ambient temperature -10℃~+50℃
              EnvironmentHumidity Maximum 95%RH (no condensing)
              Storage temperature -25℃~55℃
              Altitude <1500 meters, for every 100m increase above 1500 meters, the power is reduced by 1%
              Protection degree IP20 (higher can be customized)
              Selection table

              Common model Capacity(KVA) System voltage(V) type Protection degree
              KLD-UPQC100-3L-400V 100 400 Standard type NEMA1(IP20)
              KLD-UPQC300-3L-400V 300 400 Standard type NEMA1(IP20)
              KLD-UPQC600-3L-400V 600 400 Standard type NEMA1(IP20)
              KLD-UPQC900-3L-400V 900 400 Standard type NEMA1(IP20)
              KLD-UPQC1200-3L-400V 1200 400 Standard type NEMA1(IP20)
              KLD-UPQC1500-3L-400V 1500 400 Standard type NEMA1(IP20)
              KLD-UPQC100-4L-400V 100 400 Standard type NEMA1(IP20)
              KLD-UPQC300-4L-400V 300 400 Standard type NEMA1(IP20)
              KLD-UPQC600-4L-400V 600 400 Standard type NEMA1(IP20)
              KLD-UPQC900-4L-400V 900 400 Standard type NEMA1(IP20)
              KLD-UPQC1200-4L-400V 1200 400 Standard type NEMA1(IP20)
              KLD-UPQC1500-4L-400V 1500 400 Standard type NEMA1(IP20)

              Technical Parameters


              • Rated AC input voltage:208V-480VV(other voltage levels can be customized)

                Input Voltage range:-15%~+15%

                Grid frequency range:50Hz/60Hz±5Hz

                Wiring mode:Three-phase three-wire/Three-phase four-wire

                Multiple pcs in parallel:Support multi-module parallel connection

              • OutputFrequency:50±0.01Hz or 60±0.01Hz

                Power factor:0.99

                Voltage harmonic:≤3%

                Overload capacity:200%

              • Fast response time:<100us

                Full response time:<2.5ms

                Noise:≤60db(100% load)

                Heat dissipation mode:Intelligent air cooling

                Protection functions:Short-circuit protection, DC busbar undervoltage/overvoltage protection, power semiconductor fault protection, overload protection, etc.

              • Ambient temperature:-10℃~+50℃

                EnvironmentHumidity:Maximum 95%RH (no condensing)

                Storage temperature:-25℃~55℃

                Altitude:<1500 meters, for every 100m increase above 1500 meters, the power is reduced by 1%

                Protection degree:IP20 (higher can be customized)

              Selection table


              • KLD-UPQC100-3L-400V

                Capacity(KVA):100

                System voltage(V):400

                Type:Standard type

                Protection degree:NEMA1(IP20)

                KLD-UPQC300-3L-400V

                Capacity(KVA):300

                System voltage(V):400

                Type:Standard type

                Protection degree:NEMA1(IP20)

                KLD-UPQC600-3L-400V

                Capacity(KVA):600

                System voltage(V):400

                Type:Standard type

                Protection degree:NEMA1(IP20)

                KLD-UPQC900-3L-400V

                Capacity(KVA):900

                System voltage(V):400

                Type:Standard type

                Protection degree:NEMA1(IP20)

                KLD-UPQC1200-3L-400V

                Capacity(KVA):1200

                System voltage(V):400

                Type:Standard type

                Protection degree:NEMA1(IP20)

                KLD-UPQC1500-3L-400V

                Capacity(KVA):1500

                System voltage(V):400

                Type:Standard type

                Protection degree:NEMA1(IP20)

                KLD-UPQC100-4L-400V

                Capacity(KVA):100

                System voltage(V):400

                Type:Standard type

                Protection degree:NEMA1(IP20)

                KLD-UPQC300-4L-400V

                Capacity(KVA):300

                System voltage(V):400

                Type:Standard type

                Protection degree:NEMA1(IP20)

                KLD-UPQC600-4L-400V

                Capacity(KVA):600

                System voltage(V):400

                Type:Standard type

                Protection degree:NEMA1(IP20)

                KLD-UPQC900-4L-400V

                Capacity(KVA):900

                System voltage(V):400

                Type:Standard type

                Protection degree:NEMA1(IP20)

                KLD-UPQC1200-4L-400V

                Capacity(KVA):1200

                System voltage(V):400

                Type:Standard type

                Protection degree:NEMA1(IP20)

                KLD-UPQC1500-4L-400V

                Capacity(KVA):1500

                System voltage(V):400

                Type:Standard type

                Protection degree:NEMA1(IP20)