KLD-BMS Series

              Harmonic Protector

              Harmonic control product developed for precise instruments on the user side that are susceptible to various kinds of interferences and result in various faults. It can absorb high-frequency pulse spike and high-frequency noise signals to protect sensitive equipment on the user side.

              PRODUCT OVERVIEW

              As science and technology continues to develop, harmonics generated by nonlinear modern power equipment and devices, such as computers, lighting control systems, communication systems, network control equipment, a variety of digital office equipment, light regulation and control systems, UPS, CNC machine tools, rectifiers, precise instruments, electronic control mechanisms, etc., result in a harsh harmonic environment, posing s great threat to the normal operation of the power system and equipment. The microprocessors in electronic equipment, automatic control equipment and computers are usually more sensitive and have higher requirements for harmonic environments.

              KLD-BMS series harmonic protector can absorb harmonic interferences of various frequencies and energies. Eliminating the occurrence of harmonics at the source can automatically eliminate the random high-order harmonics and high frequency noise, pulse spike, surge and other interferences to the power equipment. Harmonic protector can purify the power supply, protect the power equipment and power factor compensation equipment, prevent the false tripping of the protection device, so as to improve the operation efficiency and reliability of the equipment, reduce the cost of equipment maintenance and repair, and prolong the service life of the equipment.

              EFFECTIVE PROTECTION AGAINST
              HIGH-FREQUENCY INTERFERENCE

              ●   Provide harmonic protection of various energies at frequencies of 1KHz-20MHz, eliminating high-order harmonics, high-frequency noise, pulse spikes, surges and other interferences.

              ●   Reduce the fault rate and misoperation of control equipment and other precise instruments to overcome the high-frequency interference caused by harmonic pollution.

              ●   Simple wiring, diverse installation positions, convenient commissioning, without routine maintenance.

              Technical Parameters

              Rated voltage 110V~690V
              Rated frequency 50Hz/60Hz
              Protection frequency 1kHz~20MHz
              Protection range Pulse withstand current≤16000A Single loop high-order harmonics(n≥20)Harmonic current≤40A
              Response time Instantaneous response time≤100us,full response time≤10ms
              Instantaneous withstand voltage Pulse withstand voltage2500V
              Leakage current ≤1.321mA
              Power consumption <0.1W
              Overload protection Supported, with front circuit breaker
              Protection degree IIP40/P54 kit can be retrofitted
              Installation method Guide rail mounted
              Altitude Conventional 2000 meters, higher altitude can be customized
              Relative humidity ≤95%RH(no condensing)
              Storage temperature -50℃~+90℃
              Temperature range -35℃~+80℃
              Execution standard IEC61000-4-5, EC60939-1-2
              GB14549-93 Quality of electric energy supply Harmonics in public supply network
              GB12325-90 Quality of electric energy supply Admissible deviation of supply voltage
              Selection table

              Model Voltage(V) Installation method Protection frequency
              KLD-BMS99-3-400V 400 Guide rail mounted 1kHz-20MHz
              KLD-BMS100-3-400V 400 Guide rail mounted 1kHz-20MHz
              KLD-BMS300-3-400V 400 Guide rail mounted 1kHz-20MHz
              KLD-BMS500-3-400V 400 Guide rail mounted 1kHz-20MHz
              KLD-BMS1000-3-400V 400 Guide rail mounted 1kHz-20MHz
              KLD-BMS1000E-3-400V 400 Guide rail mounted 1kHz-20MHz

              Technical Parameters


              • Rated voltage:110V~690V

                Rated frequency:50Hz/60Hz

                Protection frequency:1kHz~20MHz

                Protection range:Pulse withstand current≤16000A Single loop high-order harmonics(n≥20)Harmonic current≤40A

                Response time:Instantaneous response time≤100us,full response time≤10ms

                Instantaneous withstand voltage:Pulse withstand voltage2500V

                Leakage current:≤1.321mA

                Power consumption:<0.1W

                Overload protection:Provided,with front circuit breaker

                Protection degree:IIP40/P54 kit can be retrofitted

                Installation method:Guide rail mounted

                Altitude:Conventional 2000 meters, higher altitude can be customized

                Relative humidity:≤95%RH(no condensing)

                Storage temperature:-50℃~+90℃

                Temperature range:-35℃~+80℃

                Execution standard:IEC61000-4-5, EC60939-1-2;GB14549-93 Quality of electric energy supply Harmonics in public supply network;GB12325-90 Quality of electric energy supply Admissible deviation of supply voltage

              Selection table


              • KLD-BMS99-3-400V

                Voltage(V):400

                Installation method:Guide rail mounted

                Protection frequency:1kHz-20MHz

                KLD-BMS100-3-400V

                Voltage(V):400

                Installation method:Guide rail mounted

                Protection frequency:1kHz-20MHz

                KLD-BMS300-3-400V

                Voltage(V):400

                Installation method:Guide rail mounted

                Protection frequency:1kHz-20MHz

                KLD-BMS500-3-400V

                Voltage(V):400

                Installation method:Guide rail mounted

                Protection frequency:1kHz-20MHz

                KLD-BMS1000-3-400V

                Voltage(V):400

                Installation method:Guide rail mounted

                Protection frequency:1kHz-20MHz

                KLD-BMS1000E-3-400V

                Voltage(V):400

                Installation method:Guide rail mounted

                Protection frequency:1kHz-20MHz

              page top
              中国精品一级毛片免费播放,91精品国产高清在线重,日韩欧美视频一区二三区在线观看免费,中文无码久久东京热av,欧美日韩亚洲一区二区三区,免费在线观看avh片,亚洲无码高清精品,中文字母AV一区二区三区