KLD-FD Series

              Low-voltage Filter Reactor

              Filter reactors can effectively protect the capacitors, reduce overload caused by harmonics during compensation, and avoid the possibility of resonance with grid inductance.

              PRODUCT OVERVIEW

              If there are electricity loads generated by inverters, rectifiers and other devices that produce harmonics in the power grid, the capacitor cabinet needs to be equipped with filter reactors. Low-voltage filter reactors in series with capacitors can withstand the losses generated by fundamental and harmonic currents, and will not exceed the temperature range of the insulating material in normal conditions.

              KLD-FD series low-voltage filter reactors have high accuracy and linearity to withstand the switching of capacitors and will not cause saturation because of large grid harmonic distortions. Its iron core reactors designed with leakage prevention function have lower losses and noise levels.

              Low-voltage filter reactor and capacitor in series consist of low-voltage reactive power compensation device, which will provide reactive power compensation to the grid system, improve power factor, reduce losses from the line and transformer and play a vital role in supporting the voltage. It also suppresses the amplification of harmonic current, eliminates the hidden hazards of resonance, and fully protects the operation safety and service life of capacitors.

              RELIABLE OPERATION PERFORMANCE

              Excellent electrical characteristics due to high quality materials and precise mounting.

              In the production process, products are impregnated and solidified under vacuum to avoid the impact of water molecule on the performance and service life of reactor. Each reactor is equipped with an over-temperature protection point for the customer to ensure that the linkage switch can be quickly and reliably cut off under abnormal conditions.

              HIGH LINEARITY AND SHORT-TIME CURRENT

              Linearity and short-time current are important parameters, 2.0ln linearity and 50 times rated short-time current.

              The magnetic field is produced when the coil flows through the current and Reactance coefficient as the current increases. When it reaches a certain level and can not continue to enhance, i.e., "magnetic saturation", the inductance value experience a parabolic decline from a fixed value. KLD-FD series reactors will not be magnetically saturated when passing 2.01n.

              Technical Parameters

              Rated voltage 230~800V,50/60Hz
              Output power 5~100kvar
              Reactance 7%, 14% or other reactance
              Overload capacity 1.8In
              Maximum voltage 1.1Un
              Linearity 2.0In
              Cooling method Natural cooling
              Insulation between layers Nomex high-quality insulating paper
              Impregnation method Polyester resin, class H
              Insulation level Winding-iron core 3kV
              Over-temperature protection 120°C normally closed contact
              Parameter tolerance ±3%
              Altitude Conventional 2,000 meters (higher altitude can be customized)
              Ambient temperature -40℃~+45℃(up to +55℃)
              Technical Standard Complies with GB1094、VDE0550/0532、IEC76
              Selection table

              Model Capacity(kvar) Reactance Coefficient Outlet mode Temperature monitoring
              Single-phase
              KLD-FD7-5-1-230V 5 7% Side outlet Provided
              KLD-FD7-10-1-230V 10 7% Side outlet Provided
              KLD-FD7-15-1-230V 15 7% Side outlet Provided
              KLD-FD14-5-1-230V 5 14% Side outlet Provided
              KLD-FD14-10-1-230V 10 14% Side outlet Provided
              KLD-FD14-15-1-230V 15 14% Side outlet Provided
              Three-phase
              KLD-FD7-12.5-400V 12.5 7% Side outlet Provided
              KLD-FD7-15-400V 15 7% Side outlet Provided
              KLD-FD7-20-400V 20 7% Side outlet Provided
              KLD-FD7-25-400V 25 7% Side outlet Provided
              KLD-FD7-30-400V 30 7% Side outlet Provided
              KLD-FD7-40-400V 40 7% Side outlet Provided
              KLD-FD7-50-400V 50 7% Side outlet Provided
              KLD-FD7-60-400V 60 7% Side outlet Provided
              KLD-FD14-12.5-400V 12.5 14% Side outlet Provided
              KLD-FD14-15-400V 15 14% Side outlet Provided
              KLD-FD14-20-400V 20 14% Side outlet Provided
              KLD-FD14-25-400V 25 14% Side outlet Provided
              KLD-FD14-30-400V 30 14% Side outlet Provided
              KLD-FD14-40-400V 40 14% Side outlet Provided
              KLD-FD14-50-400V 50 14% Side outlet Provided
              KLD-FD14-60-400V 60 14% Side outlet Provided

              Technical Parameters


              • Rated voltage:230~800V,50/60Hz

                Output power:5~100kvar

                Reactance: 7%, 14% or other reactance

                Overload capacity:1.8In

                Maximum voltage:1.1Un

                Linearity:2.0In

                Cooling method:Natural cooling

                Insulation between layers:Nomex high-quality insulating paper

                Impregnation method:Polyester resin, class H

                Insulation level:Winding-iron core 3kV

                Over-temperature protection:120°C normally closed contact

                Parameter tolerance:±3%

                Altitude:Conventional 2,000 meters (customized for higher altitude)

                Ambient temperature:-40℃~+45℃(up to +55℃)

                Technical standards:Complies with GB1094、VDE0550/0532、IEC76

              Selection table


              Single-phase

              • Capacity(kvar):5

                Reactance Coefficient:7%

                Outlet mode:Side outlet

                Temperature monitoring:Provided

              • Capacity(kvar):10

                Reactance Coefficient:7%

                Outlet mode:Side outlet

                Temperature monitoring:Provided

              • Capacity(kvar):15

                Reactance Coefficient:7%

                Outlet mode:Side outlet

                Temperature monitoring:Provided

              • Capacity(kvar):5

                Reactance Coefficient:14%

                Outlet mode:Side outlet

                Temperature monitoring:Provided

              • Capacity(kvar):10

                Reactance Coefficient:14%

                Outlet mode:Side outlet

                Temperature monitoring:Provided

              • Capacity(kvar):15

                Reactance Coefficient:14%

                Outlet mode:Side outlet

                Temperature monitoring:Provided

              Three-phase

              • Capacity(kvar):12.5

                Reactance Coefficient:7%

                Outlet mode:Side outlet

                Temperature monitoring:Provided

              • Capacity(kvar):15

                Reactance Coefficient:7%

                Outlet mode:Side outlet

                Temperature monitoring:Provided

              • Capacity(kvar):20

                Reactance Coefficient:7%

                Outlet mode:Side outlet

                Temperature monitoring:Provided

              • Capacity(kvar):25

                Reactance Coefficient:7%

                Outlet mode:Side outlet

                Temperature monitoring:Provided

              • Capacity(kvar):30

                Reactance Coefficient:7%

                Outlet mode:Side outlet

                Temperature monitoring:Provided

              • Capacity(kvar):40

                Reactance Coefficient:7%

                Outlet mode:Side outlet

                Temperature monitoring:Provided

              • Capacity(kvar):50

                Reactance Coefficient:7%

                Outlet mode:Side outlet

                Temperature monitoring:Provided

              • Capacity(kvar):60

                Reactance Coefficient:7%

                Outlet mode:Side outlet

                Temperature monitoring:Provided

              • Capacity(kvar):12.5

                Reactance Coefficient:14%

                Outlet mode:Side outlet

                Temperature monitoring:Provided

              • Capacity(kvar):15

                Reactance Coefficient:14%

                Outlet mode:Side outlet

                Temperature monitoring:Provided

              • Capacity(kvar):20

                Reactance Coefficient:14%

                Outlet mode:Side outlet

                Temperature monitoring:Provided

              • Capacity(kvar):25

                Reactance Coefficient:14%

                Outlet mode:Side outlet

                Temperature monitoring:Provided

              • Capacity(kvar):30

                Reactance Coefficient:14%

                Outlet mode:Side outlet

                Temperature monitoring:Provided

              • Capacity(kvar):40

                Reactance Coefficient:14%

                Outlet mode:Side outlet

                Temperature monitoring:Provided

              • Capacity(kvar):50

                Reactance Coefficient:14%

                Outlet mode:Side outlet

                Temperature monitoring:Provided

              • Capacity(kvar):60

                Reactance Coefficient:14%

                Outlet mode:Side outlet

                Temperature monitoring:Provided